Hello, I'm trying to write articles pertaining to operations/process engineering from my experience. Things that stuck in my memory, mistakes, interesting projects, etc. This one is article number 9. Let me know what your thoughts are please. I have about 12 years experience as a process/operation engineer. Hoping to add more technical details to publish into a book someday.
Somewhere in Central Alberta, there is a separator named after me. And this is the story of how that came about. It was a long time ago. I do not know if itās still in service, but the memory of the separator lives on in me, and most likely also in the memory of the operator who christened it in my honor.
THE DESIGN BASIS
Early in my career, one of the tasks that I was responsible for was sizing separators. The separators can be classified into two large categories, 2 phase (vapor and liquid) and 3 phase (vapor, light liquid and heavy liquid).
Sizing is driven by flow rates, phase densities and viscosities, assumed droplet sizes, and residence time.
My design basis was:
For liquid droplets in gas: 150 µm, with a mesh pack or chevron pack at the gas outlet for additional scrubbing.
For liquid-liquid separation: 100 µm droplets, with a spec of no more than 5 vol% of heavy liquid in light liquid and vice versa. This criterion was from past company experience.
Inlet momentum: checked against the GPSA criteria which set the inlet device, from an open nozzle or half-pipe up to a Schoepentoeter.
Outlets: liquid nozzles sized to limit velocity to 1 m/s to prevent vortices, and gas nozzle momentum limited to avoid re-entrainment of liquid droplets into the outlet gas.
Applying the above criteria gave good results at oil batteries and gas plant inlet separators, and I trusted them.
PLANT VEGETA
In 2017, I came across a request to install an oil separator at Plant Vegeta, in Central Alberta. At that point in time, there was a large reserve of second hand separators that were retrofitted for use all across the province. The facility engineer in charge of installing the separator provided a gas composition, and a lab analysis for the oil with information on viscosity and density at different temperatures.
Before I undertake any separator sizing, I always book a trip to the location where I would be installing the separator to gather additional details that will be required for the project; information pertaining to sizing pumps, PSVs, flare lines, control valves, etc. During a trip to Plant Vegeta, I ran into an operator. He gave me a tour of the plant, and before I left, he told me that the separator will never work, as the feed was too cold. I recall that it was around 12C - 15C.
But hey, I was a young, energetic, and confident engineer. My separator sizing calculation performed at 12C with the properties of the oil and gas provided to me, showed a large margin for effective separation with a refurbished separator from a nearby plant. So, together with the facility engineer, I decided to go ahead and install the separator.
REALITY
About a year later, I went back to Plant Vegeta for another project. The same operator whom I had met earlier was waiting for me at the plant.
āHey, I heard you were coming back to the plant. I want to take you to āyourā separator. We at the plant named it in your honor,ā said the plant operator with a grin.
From that grin, I knew something was wrong. He grabbed a sample of the oil for me to take a look at. And there it was, at least 20% water in the oil. Every week trucks had to transport the oil to another plant for processing. The flow rates hadnāt changed, nor had the properties of the oil.
Well, after some investigation, it turned out to be the cold after all. I had installed separators for cold feed that worked well, but not all oil behaves the same. In some cases, cold oil doesnāt separate effectively from water. My best explanation is that this cold feed formed a stable emulsion, which built a rag layer that spilled over the weir into the oil chamber, carrying large quantities of water into the oil. So, yeah, that separator wasnāt named after me for being efficient, but for doing a horrendous job in separation.
WHAT IāD DO DIFFERENTLY
Now, Iām much older, and I listen to what plant operators have to say. He never told me about emulsions or rag layer, only that it wouldnāt work. Maybe I should have asked more questions. The operators who spend the most time with the plant and process are right more often than not. They may not always be able to explain the āwhyā, but they can tell you from experience if a solution will work or not.
Now, Iād also run a bottle test of the real fluid at operating conditions to check the tendency for emulsion formation when I can get a sample.
CONCLUSION
We never did do anything to help my separator. I wanted to put a small heat exchanger in front of it, but heating medium was not readily available, and the cost was prohibitive. And chemical injection was not cheap either. In the end, it was cheaper to truck the oil to another facility where it was mixed with hotter feed for separation.
It made me wonder about all the equipment I had either designed or re-rated in my short career up to that point. How many had not performed to design specifications? I did get the occasional feedback by chance or if it was an important project that I wanted to check up on. Now, I make it a point to follow up on ALL the projects I work on and ask for feedback to see if the process equipment is working satisfactorily or not. Engineering calculations are more effective when coupled with field experience and operations knowledge.